MILAT FLOOR

Care Guide

SPC Flooring Problems and Solutions

Most SPC 'faults' trace back to the subfloor, acclimation or installation — not the plank. Here is what goes wrong, and how to prevent it.

Installation & Care 6 min read Updated August 25, 2026

SPC is one of the most forgiving floors you can buy, but like any floating floor it depends on being installed correctly. When an SPC floor does misbehave, the cause is almost always the subfloor, the acclimation or the fit — not the plank itself. Knowing the common problems and their real causes lets you avoid every one of them.

Oliva Perfecta EIR SPC flooring by MILAT Floor, shown installed in a furnished interior
Oliva — Perfecta EIR collection, shown in a rendered interior.

Peaking and gaps

Peaking (joints lifting into a small ridge) and gaps (joints pulling apart) are the classic floating-floor faults. They happen when the floor cannot expand and contract freely — usually because the perimeter expansion gap was left too small, or the planks were not acclimated to the room before laying. The fix is prevention: leave the correct expansion gap around every edge and let the flooring acclimate first.

Hollow or bouncy spots

A hollow sound or slight bounce underfoot means the subfloor beneath that spot is not flat. A rigid SPC plank bridges the dip, leaving an air gap. The solution is in the preparation: the subfloor must be levelled so it is flat within tolerance before the floor goes down.

Lifting or curling edges

Edges that lift usually point to trapped moisture from a damp subfloor, or an expansion gap that was covered by skirting or a heavy item pinning the floor. Check the subfloor is dry, keep the expansion gap clear, and avoid fixing heavy units through a floating floor.

Scratches and scuffs

SPC has a tough wear layer, but grit is abrasive and unprotected furniture legs drag. Use felt pads under furniture, place doormats at entrances to catch grit, and lift rather than drag heavy items. Light surface scuffs can often be buffed away.

Fading in strong sunlight

Any floor can lighten under years of intense, direct sunlight. A quality UV top coat slows this considerably. In rooms with very strong sun, blinds or sheer curtains during peak hours protect the colour over the long term.

Close-up of the Trillis SPC plank surface — EIR embossed wood-grain texture
Surface detail: Trillis.

Quick reference: cause and prevention

ProblemUsual causePrevention
Peaking / gapsToo-small expansion gap; no acclimationCorrect perimeter gap; acclimate first
Hollow spotsUneven subfloorLevel the subfloor before laying
Lifting edgesDamp subfloor; pinned floorDry subfloor; keep gap clear
ScratchesGrit; dragged furnitureFelt pads; doormats; lift don't drag
FadingProlonged direct sunUV top coat; blinds at peak hours

Squeaks and clicks underfoot

A squeaking SPC floor is not the plank complaining; it is movement somewhere it should not be. The usual suspects are debris left on the subfloor grinding under the boards, a high spot the floor rocks over, or joints that were never fully locked and now rub as they flex. Trace the noise to its area, and if it sits near a wall, check first that skirting or trim has not been fixed through the flooring, pinning it. Persistent squeaks over a wavy subfloor only truly resolve by lifting that section and levelling, which the click system fortunately makes possible.

Stains that come from underneath objects

Some marks are chemical, not mechanical. Rubber-backed rugs, cheap mats and certain furniture feet can react with vinyl surfaces over time and leave a yellowish shadow that no cleaner removes, a process called antioxidant staining that affects the whole resilient flooring category. Prevention is the only cure: choose mats labelled safe for vinyl floors, use felt rather than rubber under furniture, and lift and move rugs occasionally. The same advice covers hair dyes, solvents and strong disinfectants; wipe aggressive chemicals up immediately rather than letting them sit.

Sunrooms, conservatories and extreme temperature swings

SPC is the most temperature-stable floor in the vinyl family, but glazed rooms are their own climate: afternoon heat behind glass, sharp cold on winter nights, sometimes in the same week. The floor can serve here, with discipline. Respect the expansion gap generously, keep large fixed loads from pinning the floor, and use shading to blunt the harshest solar gain. In fully unheated spaces that freeze, follow the manufacturer's stated temperature range rather than assumptions. Most sunroom failures blamed on flooring turn out to be a standard indoor installation put into a non-standard climate.

Damaged click joints: the installer's own goal

A click profile is precise machining, and it only works undamaged. Driving planks together with a bare hammer, forcing a misaligned joint, or repeatedly opening and closing the same connection can bruise the locking edge, and a bruised joint holds neither tight nor flat. The symptom appears later as a gap or a lip along one seam while the rest of the floor sits perfectly. During installation, use a tapping block and pull bar, and if a joint resists, stop and find out why; the resistance is information, usually debris or misalignment, never a lack of force.

Diagnose before you blame: reading a floor like a claims inspector

When a floor misbehaves, the pattern tells the story. Problems along one wall point to expansion gaps or pinned edges; problems in traffic lanes point to subfloor flatness; problems near glass point to heat; problems everywhere at once point to product or a fundamentally wrong installation. Photograph the symptom, note where and when it appears, and check the simple causes before lifting anything. Manufacturers see this daily, and a clear description with photos gets a useful answer fast, while a floor torn up in frustration destroys the evidence that would have solved it.

Talk to MILAT Floor

Samples, specifications, OEM & private label, wholesale or export — our team is ready.

Contact Us

FAQ

Frequently asked questions

Why is my SPC floor lifting or peaking?

Peaking and lifting almost always mean the floor cannot expand freely — usually a too-small perimeter expansion gap, planks that were not acclimated, or a damp subfloor. Correcting the gap and acclimation prevents it.

Why does my SPC floor feel hollow in places?

A hollow or bouncy spot means the subfloor under that area is not flat, so the rigid plank bridges a dip and leaves an air gap. The subfloor must be levelled before installation.

Are SPC flooring problems the floor's fault or the installation?

Almost always the installation or preparation — subfloor flatness, moisture, acclimation and the expansion gap — rather than the plank itself. Correct installation prevents nearly all common problems.

Can scratches on SPC flooring be repaired?

Light surface scuffs can often be buffed out. Prevent scratches with felt pads under furniture, doormats to trap grit, and by lifting rather than dragging heavy items.

Does SPC flooring fade in sunlight?

Prolonged, intense direct sunlight can lighten any floor over years. A quality UV top coat slows fading significantly, and blinds during peak sun protect the colour further.

How do I stop my SPC floor from gapping?

Acclimate the planks in the room before installation and leave the correct expansion gap around the whole perimeter so the floor can move with temperature changes without pulling apart.

Why does my SPC floor squeak when I walk on it?

Squeaks come from movement: debris under the boards, a high spot the floor rocks over, unlocked joints, or trim pinning the floor. Find the area, check the simple causes first, and level the subfloor under that section if the noise persists.

Can rubber mats or rug backings stain SPC flooring?

Yes. Some rubber compounds react with vinyl surfaces over time and leave a permanent yellowish shadow. Use mats and rug pads labelled safe for vinyl floors and felt pads instead of rubber under furniture.

Can SPC flooring be installed in a conservatory or sunroom?

Often yes, if the space stays within the manufacturer's temperature range. Use generous expansion gaps, avoid pinning the floor under heavy fixed loads, and shade the worst solar gain. Unheated spaces that freeze need a specific check first.